Five stages from mains to load, each with a measured pass criterion: 198 to 242 V AC, CV reads nameplate open circuit, CC at its window ceiling is normal, a 5 m 24 V strip reads about 8 ohms.
"Light is out, swap the driver" is the most common action on site and the one most often done wrong. In a no-output call the driver itself is far from the only cause - upstream supply, terminal crimps, a shorted load or an open strip all present identically. The point of the ladder is not to look professional; it is to narrow the fault to one stage with a single multimeter so the replacement is right the first time.
The one-sentence rule: bisect from upstream down, one number per stage
Step
What to measure
Pass criterion
If it fails
1 Mains
AC voltage upstream of the driver
198-242 V on a 220 V system; 207-253 V on 230 V
Distribution, breaker, switch, series dimmer
2 Input terminals
Voltage at the driver input terminals
Within 1 V of upstream
Loose terminal, bad crimp, open neutral
3 Open circuit
Output with the load disconnected
CV = nameplate +/-5%; CC = window ceiling
Driver failed, or protection not reset
4 Loaded
Output with the load connected
Sag 5 percent or less and stable
Overload or short protection, go to step 5
5 Load side
Resistance, continuity, polarity
See the calculation below
Open strip, short, reverse polarity, terminal fault
The five-step decision flow
Every "no" points at one specific fault domain; walk down the rows and you localise it in five minutes
Step 3 is where most misdiagnoses happen: constant current open-circuit voltage
This single point causes more unnecessary swaps than anything else. Disconnect the load on a constant-current driver and the output rises to the window ceiling - that is how the topology works: the current setpoint is fixed, and with no load the only thing it can do is push voltage up.
A constant-current unit with a 12-48 V window reading 46-48 V open circuit is normal, not "overvoltage damage"
Constant voltage is the opposite: open circuit must equal nameplate, so a 24 V unit should read 22.8-25.2 V (plus or minus 5 percent); zero is the anomaly
Judge on voltage only - never by whether it sparks
Whether a constant-current driver may sit open circuit indefinitely varies by design (some cycle, some hold at the ceiling). Short open-circuit measurements during diagnosis are fine; for long-term no-load behaviour, follow your spec.
Step 5: clear the load question with the resistance range
Normal strip resistance is computable, so any deviation is a finding:
R = U x U / P
24 V, 5 m, 14.4 W/m - P = 72 W - R = 576 / 72 = 8 ohms
12 V, 5 m, 14.4 W/m - P = 72 W - R = 144 / 72 = 2 ohms
Measured
Verdict
Action
Close to calculated (plus or minus 20 percent)
Load is fine
Back to step 4; the fault is upstream
Infinite (open)
Broken board, pulled joint, cracked solder
Measure section by section; joints fail first
Near zero (for example 0.3 ohm)
Short
Look for crushed strip, screws through the board, clipped strand whiskers
Clearly high
Reverse polarity or a diode-type device in the run
Check wire colours against the polarity marks
Measure two commonly missed points while you are there:
Terminal contact resistance: the drop from the driver output terminal to the strip start; under load anything above 0.5 V means re-crimp (the full method is in the voltage drop and cable size table)
0-10 V signal pair: short the two signal wires at the driver and the light should go to minimum; left floating, most units return to full. If floating still gives nothing, the fault is in the driver or upstream, not the dimmer
Three things that look like a dead driver but are not
Triac dimmer stuck at minimum: at very low output the driver never starts. Turn it to maximum; if still dark, bypass the dimmer and run mains straight in as a check.
Thermal protection not yet reset: re-energising immediately after a trip does nothing. Wait 30 s to 2 min; if it lights normally afterwards, nothing is broken.
Several units dark at once means look upstream: multiple drivers failing simultaneously is close to impossible. Check the breaker and the group switch first - the same fault domain as inrush current and breaker sizing.
Evidence to record before you swap (copy this list)
Nameplate photo of the driver (model, input and output ratings, certification marks legible)
Four readings: input voltage, open-circuit voltage, loaded voltage, load resistance
Installation photo: sealed cavity or not, metal surface for heatsinking, how many units packed together
Symptom wording: dark / flashes then dies / runs a few seconds then dies / dies only at low dimming
Which of the five steps you have already run (tick them off)
With those five, a supplier can usually decide in one pass whether to swap the unit or change the installation. Only swap when all five steps pass and all four readings are on record - otherwise the replacement is likely to fail the same way.
Before swapping the unit, spend five minutes on the ladder: send us the driver model, measured input voltage, open-circuit voltage, loaded voltage and load resistance, and we will tell you whether it is the driver, the load or the upstream supply. Contact →