Wiring & calculations
Copper cross-section required for 12V and 24V constant-voltage strips by load and cable run, with the formulas and when to raise the voltage instead of thickening the cable.
On constant-voltage strip jobs the usual problem is not a failed driver but voltage drop at the far end. This chart gives the copper cross-section for 12V and 24V systems at common loads and distances, working back from a 5% drop limit.
The columns are the one-way cable run (driver to the first LED, in metres) and the rows are the total load. The cell is the copper cross-section in mm² that keeps the drop within 5%, rounded up to the next standard size.
Example: a 24V system, 100 W total, 10 m run → 1.5 mm². If only 0.75 mm² is on site, the far end will be visibly dim.
| Total load | 5 m | 10 m | 15 m | 20 m | 30 m |
|---|---|---|---|---|---|
| 30 W | 0.75 | 1.5 | 2.5 | 4 | 6 |
| 60 W | 1.5 | 4 | 6 | 6 | 10 |
| 100 W | 2.5 | 6 | 10 | 10 | >10 |
| 150 W | 4 | 10 | >10 | >10 | >10 |
| 200 W | 6 | 10 | >10 | >10 | >10 |
| 300 W | 10 | >10 | >10 | >10 | >10 |
| Total load | 5 m | 10 m | 15 m | 20 m | 30 m |
|---|---|---|---|---|---|
| 30 W | 0.5 | 0.5 | 0.75 | 0.75 | 1.5 |
| 60 W | 0.5 | 0.75 | 1.5 | 1.5 | 2.5 |
| 100 W | 0.75 | 1.5 | 2.5 | 2.5 | 4 |
| 150 W | 1 | 2.5 | 4 | 4 | 6 |
| 200 W | 1.5 | 2.5 | 4 | 6 | 10 |
| 300 W | 2.5 | 4 | 6 | 10 | >10 |
Every figure here comes from those formulas and matches the sizing calculator — the two cross-check each other.
Once the answer passes 4 mm², more copper is usually the wrong spend. In order of effectiveness:
© 2026 YFX. Figures are for selection purposes. Always follow the datasheet and local wiring regulations for final installation.