A 9 to 48 V constant-current driver does not hold regulation across the whole span. String voltage peaks cold and bottoms out hot, and crossing either end fails differently. Cold and hot string voltage formulas, series count limits, and three worked examples.

Last updated:2026-11-02

On this page
  1. The one-sentence rule: the window clamps your string count, and cold sets the ceiling
  2. Crossing either end looks completely different
  3. Three worked examples (white 2835, nominal Vf 3.0 V at 25 degrees C, bin spread 0.1 V per LED)
  4. Formulas to apply directly
  5. Five frequent mistakes
  6. Acceptance checklist

A constant-current driver labelled 9 to 48 V does not regulate across that entire span. It holds the set current only inside the range where its output stage can work, and the two ends of that range fail in completely different ways. Sizing the string is arithmetic: the cold state sets the upper limit, the hot state sets the lower one, and power has to pass a third check.

The one-sentence rule: the window clamps your string count, and cold sets the ceiling

The three examples below all use a constant-current unit of the H19 class: 9 to 48 V output, 10 to 52 W, eight current steps set by DIP switch.

Crossing either end looks completely different

DirectionWhat triggers itWhat you see on siteHow to confirm
Hitting the ceiling (overvoltage)High cold Vf plus too many LEDs in seriesFlashes once at switch-on and dies, restarts repeatedly; clusters in winter or early morningPower up from cold and measure the output; a transient spike near the window ceiling confirms it
Dropping under the floorToo few LEDs in seriesBrightness drifts with temperature, drops out at low dimming, faint noise from the driverMeasure steady-state output after 30 minutes; below the window floor confirms it
Inside the window but over powerVoltage x current exceeds ratingOutput current is folded back, brightness is short of targetClamp the current; measured value clearly below the DIP setting
The first row is the one most often misread as a failed driver. The driver is protecting itself; the wrong parameter is the string count.

Three worked examples (white 2835, nominal Vf 3.0 V at 25 degrees C, bin spread 0.1 V per LED)

Example 1: ten in series, works

Example 2: sixteen in series to save a driver, out of bounds

Example 3: twelve per string, three strings in parallel, works but needs ballasting

String voltage inside a 9 to 48 V window: highest cold, lowest hot (three examples) 9 V floor 48 V ceiling 0 9 24 48 60 V ex 1: 10 LEDs 28.8 to 31.5 V, passes ex 2: 16 LEDs 50.4 V, out of bounds ex 3: 12 LEDs x 3 34.6 to 37.8 V, passes left dot = hot string voltage, right dot = cold; red dashed line is the 48 V ceiling
Ten and twelve LEDs fit the same driver; sixteen only fail once cold - the ceiling must be set from cold Vf

Formulas to apply directly

Vf_cold = Vf_25 + 0.002 x (25 - T_cold) + dVf_bin     cold forward voltage per LED
Vf_hot  = Vf_25 - 0.002 x (T_j - 25)                  hot forward voltage per LED

N_max = floor(0.9 x V_win_max / Vf_cold)              series ceiling, set cold
N_min = ceil (1.1 x V_win_min / Vf_hot)               series floor, set hot
n_par = floor(0.8 x I_rated / I_string)               parallel strings allowed
P_ok  = V_hot x (n_par x I_string) < 0.8 x P_rated    power check

Vf_25      nominal forward voltage at 25 degrees C
0.002      temperature coefficient, about -2 mV per degree C (order of magnitude, use the LED datasheet)
dVf_bin    bin spread, use 0.1 V; zero if one bin is specified
Do not reverse the order: ceiling from cold, then floor from hot, then power. Size from the hot state and winter will always find you.

Five frequent mistakes

  1. Using nominal Vf: 48 / 3.0 gives 16, but cold and bin spread leave you 13
  2. Changing LED supplier without recounting: bin centres can differ by 0.1 to 0.2 V per LED, which is 1 to 2 V over ten
  3. Paralleling strings bare: without measuring each string, one ages first and the luminaire goes patchy
  4. Raising the current step without checking power: 48 V at the 1.05 A step is 50.4 W, close to the 52 W limit, and fold-back kicks in
  5. Treating the window as a constant-voltage rail: on a constant-current driver the output voltage is a result, not a setting

Acceptance checklist

  1. Measure the output transient at cold switch-on: peak at or below 0.9 x the ceiling (43 V on a 48 V unit)
  2. Measure steady state after 30 minutes: at or above 1.1 x the floor (10 V on a 9 V unit)
  3. Clamp each string: spread between parallel strings 10 percent or less, add ballast resistors if not
  4. Check total current against the DIP setting: clearly low means the unit is folding back
  5. Compute output power: steady-state voltage x total current at or below 0.8 x rated
  6. Dim down to 10 percent: no dropout and no flicker means the low end is still inside the window

Constant-current unit H19 (9 to 48 V, 10 to 52 W, eight switchable current steps) suits downlights and spotlights where the LED count is fixed. If the load is self-limited, such as strip or modules, use a constant-voltage unit instead - H01, K01 or S01 - and the reasoning is in constant voltage versus constant current. Current and power conversion runs in the LED driver sizing calculator, and why the 0.8 factor shapes case temperature and life is in how much power headroom.

The 0.002 V per degree C coefficient and the 0.1 V bin spread are typical orders of magnitude; take the real values from the LED datasheet. Any change to the electrical installation must follow local rules and the latest requirements of the certifying body.
Send us the LED Vf, LEDs per string, number of parallel strings and target current. We will check whether the string voltage sits inside the window, whether you need ballast resistors, and which current step to dial in. Contact →